Air-air pneumatic pressure multiplier (booster) with 40 diameter pressure regulator. This device allows the air pressure available at its inlet to be multiplied by two. Pressure indicator manometer not included, must be ordered separately.

Reference: 9002200

Multiplier scheme with regulator

Logo-Metal-Work

Representative image for illustrative purposes, the item supplied will correspond to the indicated specifications.

No queries yet, leave the first!
 

40 diameter air-air pressure multiplier , without air pressure regulator at the outlet. The air pressure multiplier, also called booster, is an automatic device that compresses the incoming air, releasing at the outlet a flow of air with double pressure with respect to the inlet, multiplying by two the value of the air pressure in its entrance.

This device is usually used where it is necessary to intensify, at a certain location, the supply pressure of one or more pneumatic actuators. It is an entirely pneumatic device, it can be used in environments where the use of electrical devices is discouraged. The multiplier is equipped with non-return valves that allow the outlet pressure to be maintained, even when the inlet pressure is interrupted.
Pressure multipliers do not replace compressors, but provide a higher pressure value for a limited time. They are often used to increase the force of pneumatic cylinders.

To avoid fluctuations in the outlet pressure, it is advisable to install a tank after the multiplier.

The pressure gauge for pressure indication is not included in the supply, it must be ordered separately.

Technical characteristics:

  • Manufacturer: Metal Work .
  • Reference: 9002100
  • Diameter: 40mm.
  • Fluid: Air without lubrication, if lubricated air is used, it must be continuous.
  • Thread: G 1/8.
  • Inlet pressure:
    • MPa: 0.2...1.
    • bar : 2...10.
    • psi: 29..145.
  • Outlet pressure:
    • MPa: max 2.
    • bar : max 20.
    • psi: max 290
  • Operating temperature: -10º ... 60º.
  • Weight: 1,380 gr.
  • Fixing: Possibility of fixing to wall or panel.
  • Mounting position: in any position.
  • Pressure Regulator installed.

Attention: It is necessary to unplug the power and discharge the use circuit before carrying out any intervention with the device.

Dimensions:

Booter 40 dimensions without regulator

Flow curves:

40 booster flow curves

To avoid fluctuations in the outlet pressure, it is advisable to install a tank after the multiplier. If a tank is used, the tank filling times must be taken into account. Below we provide a filling curve for a 10-liter tank.

10 liter tank filling curves

Installation note: The pressure regulator is installed at the inlet of the multiplier, if for example, we need to have 10kg/cm2 at the outlet, we have to set the regulator to a pressure of 5kg/cm2 since the multiplier provides double the pressure at the exit from the one at the entrance.

Material for professional use, install in compliance with the regulations in force at the installation site.

Questions

Be the first to ask a question about this product!

Question about the product

* Required fields
(read)

Responsible: ADAJUSA (CONSTRUCCIONES PBR, S.L.), purpose: Respond to requests for information, legitimacy: consent of the interested party, recipients: data will not be communicated to third parties, rights: Access, rectify and delete data, as well as other rights, as explained in the additional information. (read)