Transformer 200VA E:230/400V S:24V IP-00
Transformer 200VA E:230/400V S:24V IP-00

Transformer 3000VA E:230-400V S:12V IP-00

Special manufacturing material
€372.94 Tax included

€310.78 tax excl.

Single-phase switching transformer for command, control, and general uses, with an input voltage of 230-400 Vac and an output voltage of 12 Vac. The transformer has a power output of 3000 VA and an IP00 protection rating.

Reference: TR3000 230-400/12

Single-phase transformer diagram 400-230 output 12

Representative image for illustrative purposes, the item supplied will correspond to the specifications indicated.

 

No queries yet, leave the first!
 

Single-phase transformer with 230-400Vac input and 12Vac output, 3000VA power. Varnished transformer with IP-00 protection. Maximum current supplied is 250A (apparent current).

The main application of this type of transformer is for command and control in industrial automation systems and for general applications. They are designed to power electrical devices where galvanic isolation between circuits is required. They are protected against moisture by resin impregnation.

These types of transformers are fully reversible.

Technical characteristics of the transformer:


  • Reference: TR-3000 -2 / TR3000 230-400/12
  • Transformer type: Single-phase
  • Transformer primary voltage: 230-400 Vac
  • Transformer secondary voltage: 12 Vac
  • Transformer rated power: 3000 VA
  • Maximum intensity in the secondary (In): 250 A
  • Windings: Thermal class N 200ºC.
  • Insulators: Thermal class B 130ºC.
  • Frequency: 50/60 Hz.
  • Protection: IP-00.
  • Transformer test voltage:
    • 5 KV between windings.
    • 2.5 KV between windings and ground.
  • Ambient temperature: Ta= 25ºC.
  • Transformer encapsulation: varnished.
  • Transformer mounting: using screws.
  • Certificate: UNE-EN61558-2-6

Dim_transformer_monophasic_ip00

  • A: 180 mm
  • B: 165 mm
  • C: 165 mm
  • Weight: 19.5 Kg
The transformer is supplied without any type of overload protection; protection is required to prevent overloading. The indicated power and current are apparent; the active current supplied by the transformer will depend on the power factor of the connected load.
Professional use material, install in compliance with the regulations in force at the place of installation.

Questions

Be the first to ask a question about this product!

Question about the product

* Required fields
(read)

Responsible: ADAJUSA (CONSTRUCCIONES PBR, S.L.), purpose: Respond to requests for information, legitimacy: consent of the interested party, recipients: data will not be communicated to third parties, rights: Access, rectify and delete data, as well as other rights, as explained in the additional information. (read)