Transformer 200VA E:230/400V S:12/24/36/48 IP-00
Transformer 200VA E:230/400V S:12/24/36/48 IP-00
Transformer 200VA E:230/400V S:12/24/36/48 IP-00
Transformer 200VA E:230/400V S:12/24/36/48 IP-00

Transformer 200VA E:230/400V S:12/24/36/48 IP-00

€75.10 Tax included

€62.07 tax excl.

Single-phase transformer for command, control and general uses. The power of the transformer is 200VA, the degree of protection of the transformer is IP-00. This range of transformers has four output voltages 12,24,36 or 48V, each of them selectable by means of supplied jumpers.

Reference: M200

Esquema transformador multitensión

Representative image for illustrative purposes, the item supplied will correspond to the specifications indicated.

No queries yet, leave the first!
 

Single-phase varnished isolatingtransformer for control and switchgear, transformer with four possible output voltages, each of them selectable by means of supplied jumpers.

Technical characteristics of the transformer:


  • Reference: M200
  • Transformer primary voltage: 230/400V.
  • Transformer secondary (output) voltage: 12/24/36 or 48V, selectable by means of jumpers.
  • Transformer power: 200 VA.
  • Maximum current (In): 4.16A
  • Windings: Thermal class N 200ºC.
  • Selection: of voltages by means of jumpers.
  • Insulation: Thermal class B 130ºC.
  • Frequency: 50/60 Hz.
  • Protection: IP-00.
  • Transformer test voltage
    • 5 KV between windings.
    • 2.5 KV between windings and ground.
  • Ambient temperature: Ta= 25ºC.
  • Transformer encapsulation: Varnished.
  • Transformer mounting: by means of screws.
  • Certificate: UNE-EN61558
Dimensiones transformador multitensión Sevein IP-00
The transformer is supplied without any type of overload protection, it is mandatory to install them. The rated power is understood on the higher voltage tap, on the lower voltage tap it will be reduced proportionally to the voltage. The maximum current supplied (In) cannot be exceeded by any of the voltage sockets when only one of them is used, if both voltage sockets are used simultaneously, the sum of both currents cannot exceed the rated current (In).

Professional use material, install in compliance with the regulations in force at the place of installation.

Questions

Be the first to ask a question about this product!

Question about the product

* Required fields
(read)

Responsible: ADAJUSA (CONSTRUCCIONES PBR, S.L.), purpose: Respond to requests for information, legitimacy: consent of the interested party, recipients: data will not be communicated to third parties, rights: Access, rectify and delete data, as well as other rights, as explained in the additional information. (read)